Conductivity Cells

 

Conductivity Cell Families

A wide range of conductivity cells are available for every application. These conductivity cells feature

built-in temperature compensation; high, standard, and low conductivity measuring ranges, cell constants from

0.1 to 10 cm-1 and a variety of probe materials including epoxy/graphite, glass/platinum, and stainless steel.

 

4-Electrode Conductivity Cells

DuraProbe 4-electrode cells provide the highest accuracy for demanding laboratory or field applications. The

4-electrode design compensates for electrode fouling, cable and connector resistance, polarization errors, and

fringe field interference errors. The epoxy/graphite cell material is extremely durable and chemically resistant.

DuraProbe conductivity cells are ideal for high and standard conductivity samples and difficult samples such as

wastewater, runoff water, and mud.

 

2-Electrode Conductivity Cells

The 2-electrode cells are able to measure low, standard, and high conductivity samples, depending on the

cell constant. Cells with a 0.1 cm-1 cell constant are ideal for low ionic strength solutions, de-ionized water, and ultra

pure water. Glass/platinum cells are the best for chemically reactive conductivity samples, since the cell material is highly

chemical resistant.

 

 

Recommended Accessories: Cat. No. Conductivity Solution

011001 Conditioning solution for 011050, 011050A, and 011050MD cond. cells

011008 100 µS/cm Cond/TDS Std., 5 x 60 mL

01100910 147 µS/cm Cond Std., 10 pouches

011007 1413 µS/cm Cond/TDS Std., 5 x 60 mL

01100710 1413 µS/cm Cond/TDS Std., 10 pouches

011006 12.9 mS/cm Cond/TDS Std., 5 x 60 mL

01100610 12.9 mS/cm Cond/TDS Std., 10 pouches

011005 111 mS/cm Cond Std., 5 x 60 mL

01100510 111 mS/cm Cond Std., 10 pouches

990106 0.1 M KCl Cond Std., 457 mL

Documentation

Download:
Download:

Catégorie

013005A/ 013010A/ 013005D/ 013010D/013005MD/ 013010MD/ 013025MD   013610/ 013660/ 013605MD/ 013610MD
013005A/ 013010A/ 013005D/ 013010D/013005MD/ 013010MD/ 013025MD Rugged DuraProbe
4-electrode
conductivity cell 
  013610/ 013660/ 013605MD/ 013610MD Reliable DuraProbe
4-electrode
conductivity cell 
011020/ 011020A/ 9902BN   013016A/ 013016D/ 013016MD
011020/ 011020A/ 9902BN Platinized 2-electrode conductivity cell
Voor lage gebied 
  013016A/ 013016D/ 013016MD 2-electrode
conductivity cell for
ultra-pure water 
011010/ 011010A   011050/ 011050A/ 011050MD
011010/ 011010A Chemical resistant
2-electrode
conductivity cell 
  011050/ 011050A/ 011050MD Nauwkeurige en robuuste 2-electrode
conductivity cell 
011510/ 011510MD   018020MD
011510/ 011510MD Rugged 2-electrode
conductivity cell 
  018020MD High range
2-electrode
conductivity cell 
014005  
014005 Chemical resistant
3-electrode
conductivity cell 
 
Navigation
Dependences

Language ( French)
English 
Traduction

Information
Demande d' InformationDemande d' Information

Conductivity Cells